[{"sku":"S-UCC-M001","title":"Electronic Switch Pulse Input Adapter - 1 meter Sensor","subtitle":null,"variant_product_name":null,"unit_price":"115.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"5.00","parcel_width":"1.50","parcel_height":"5.50","parcel_weight":"0.25","sellable":true,"published":true,"product_page_url":"\/products\/sensors\/s-ucc-m001","nid":"12391","product_description":"<p>Connects sensors with pulse outputs to data loggers with Smart Sensor inputs. Compatible with electronic switch closures such as FET or open-collector outputs, or CMOS-level logic signals with a maximum input frequency of 120 Hz (120 pulses per second). <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"34c982c9-4003-4cf7-8d65-a6ae3eca1df4\" href=\"\/node\/7931\" rel=\"noopener\" target=\"_blank\">See how the pulse recorder works<\/a>.<\/p>\r\n","add_on_products":{"items":["ZIP-KIT"]},"applications":["Environmental Research & Protection","Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Energy Monitoring","Indoor Environment","Shipping & Storage Monitoring","Agricultural Monitoring","Agricultural Research","Irrigation & Water","Crop Production","Orchard & Vineyard","Precision Livestock"],"brand":"HOBO","compatible_items":{"Data Logger":{"USB_Data_Loggers_requires_external_sensors":{"items":["H21-USB","H22-001","U30-NRC"]},"USB_w_external_sensors":{"items":["U30-NRC-SYS-C"]},"Web_based_Monitoring_Systems_via_remote_communication":{"items":["RX2100","RX2100-WL","RX3000"]}},"Sensor":{"Kilowatt_Hours":{"items":["T-WNB-3D-240","T-WNB-3D-480","T-WNB-3Y-208","T-WNB-3Y-208-P","T-WNB-3Y-208-P","T-WNB-3D-240","T-WNB-3D-480","T-WNB-3Y-208"]}},"Accessory":{"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"Extension_Cables":{"items":["S-EXT-CASE2","S-EXT-M002","S-EXT-M005","S-EXT-M010","S-EXT-M025"]}}},"country":"US","field_documents":[{"nid":9276}],"environment":["Indoor","Outdoor"],"measurement":["Pulse Input "],"not_a_sku":"0","parcel_status":"default","features":"<ul>\n\t<li>Plug-n-play adapter for pulse output sensors<\/li>\n\t<li>Automatically recognized by H21, H22, U30, and RX Series data loggers<\/li>\n\t<li>1m cable length (extension cables available)<\/li>\n<\/ul>\n","product_price":"115.00","specifications":[{"type":"Simple text","revision_default":"1","field_description":"<p><strong>Maximum input frequency:<\/strong> 120 Hz (120 pulses per second)<br>\n<strong>Measurement range:<\/strong> 0 \u2013 65,533 pulses per logging interval<br>\n<strong>Resolution:<\/strong> 1 pulse<br>\n<strong>Lockout time:<\/strong> 45 \u00b5s \u00b1 10%<br>\n<strong>Recommended input type:<\/strong> Electronic solid state switch closure or CMOS-level digital output (example: FET, opto-FET or open collector)<br>\n<strong>Preferred switch state:<\/strong> Active low input Normally open<br>\n<strong>Edge detection:<\/strong> Falling edge, Schmitt Trigger buffer (logic levels: low \u2264 0.6 V, high \u2265 2.7 V)<br>\n<strong>Minimum pulse width:<\/strong> 1 ms<br>\n<strong>Input\/output impedance:<\/strong> 100 K\u03a9<br>\n<strong>Open circuit input voltage:<\/strong> 3.3 V<br>\n<strong>Maximum input voltage:<\/strong> 3.6 V<br>\n<strong>User connection: <\/strong>24 AWG wires, 2 leads: white(+), black(-)<br>\n<strong>Operating temperature range:<\/strong> -40\u00b0 to 75\u00b0C (-40\u00b0 to 167\u00b0F)<br>\n<strong>Overall cable length:<\/strong> 1 m (3.3 ft.)<br>\n<strong>Housing:<\/strong> Weatherproof PVC housing protects input adapter electronics<br>\n<strong>Housing dimensions: <\/strong>14 x 0.95 cm (5.5 x 0.375 in.)<br>\n<strong>Weight:<\/strong> 310 g (11 oz.)<br>\n<strong>Bits per sample:<\/strong> 16<br>\n<strong>Number of data channels:<\/strong> 1<br>\n<strong>Measurement averaging option:<\/strong> No (reports the number of pulses over the logging interval)<\/p>"}],"product_status":"active","product_type":"Sensors","warranty":"1","warranty_premium":"1","digital_item":"0"},[{"nid":"9276","uuid":"81af014d-9203-4288-9d7b-07b29ed02f8c","vid":"10121","langcode":"und","revision_timestamp":"1645725808","status":"1","title":"Pulse Input Adapter (S-UCC-M00x, S-UCD-M00x) User's Manual","created":"1202420115","changed":"1645725808","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/13577-man-s-ucx","pid":"17876","langcode":"und"},"archive_resource":"0","associated_products":["S-UCC-M001","S-UCC-M006","S-UCD-M001","S-UCD-M006"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/13577-F%20MAN-S-UCx.pdf"},"documentation_id":"13577-MAN-S-UCx","documentation_is_datasheet":"0","resource_type":"Documentation"}]]
S-UCC-M001
Electronic Switch Pulse Input Adapter - 1 meter Sensor
Connects sensors with pulse outputs to data loggers with Smart Sensor inputs. Compatible with electronic switch closures such as FET or open-collector outputs, or CMOS-level logic signals with a maximum input frequency of 120 Hz (120 pulses per second). See how the pulse recorder works.
If you've shopped with us before, you can continue using your existing
email address. You may need to reset your password when signing in
for the first time.